Diagnosis and resolution of electrical discharges in ohmic heating systems for the food industry
A destructive electrical phenomenon (recurring, unpredictable and costly) identified through field measurements, FEM simulation and controlled experimental reproduction.

Ohmic heating is a well-established technology for the heat treatment of liquid foods: it utilises the direct passage of an electric current through the product to heat it from within, ensuring thermal uniformity and shorter processing times compared to conventional methods. In the most advanced industrial systems, this technology enables the pasteurisation and continuous processing of fluids, even those with a high protein content, with superior processing results compared to other technologies used in this sector.
However, as is often the case with technologies operating at high electrical power densities, anomalous phenomena may arise that are difficult to diagnose using traditional instruments. This case study describes a project in which InovaLab was called upon to identify the cause of destructive electrical discharges within an industrial ohmic heating system, to reproduce them in a controlled manner, and to formulate concrete recommendations for their elimination.
Background: An anomalous and costly electrical phenomenon

The client, a company with solid experience in designing industrial egg processing plants, was facing a recurring problem with a high economic impact: unpredictably, during the normal production cycle, violent electrical discharges occurred in the area adjacent to the ohmic heating electrode.
These discharges did not just interrupt the process. They caused the product being processed to burn and, even more critically, locally degraded and melted system components, leading to direct consequences such as:
Unplanned downtime;
High replacement costs for damaged components;
Significant product waste;
Inability to guarantee process continuity and quality.
The phenomenon occurred in a statistically random manner, making it neither reproducible nor predictable. This rendered any attempt at empirical correction completely ineffective and potentially expensive.
Although the client had already carried out field observations and preliminary internal analyses, they were unable to isolate the root cause. A different approach was clearly needed: one that was scientific, methodical, and grounded in multidisciplinary expertise.
The engineering challenge

In ohmic heating, the liquid product flows through a conductive tube while an electrical voltage is applied to the electrodes at the ends: the current passing through the fluid heats it via the Joule effect. The system operates at high voltage and high frequency, with power levels on the order of several kW per individual section.
The presence of electrical discharges indicated the existence of zones with a very high concentration of the electric field, but it was necessary to understand where, why only under certain operating conditions, and above all, how to identify the cause rigorously, without relying on long-term empirical testing.
To tackle the project, the integration of multiple areas of expertise was required—rarely concentrated within a single team and all part of InovaLab’s operational know-how:
The physics of electrical discharge in multiphase environments
Thermographic surveys and analyses of operational industrial systems

Find out more about the principles of resistive heating through the passage of an electric current.
Fill out the form to download the full document.
Measurements, simulations and controlled reproduction
The project was carried out in three sequential phases, each aimed at reducing uncertainty and getting closer to the root cause.

Stage 1: Experimental measurements
The first step was to conduct a measurement campaign at the client’s facility, attempting to reproduce the operating conditions under which the phenomenon occurred. Ad-hoc measurement systems designed for high-voltage environments were used, alongside thermographic analysis for mapping the surface temperatures of the components during operation.
The measurements allowed for the electrical characterization of the system—specifically the waveform, transferred power, and section impedance—and helped exclude several initial hypotheses. However, they were not sufficient to reproduce the phenomenon because the anomaly did not occur during the measurement session, confirming its probabilistic nature.
This result, while apparently negative, was actually highly informative: it steered the analysis toward numerical modeling as a tool to explore critical conditions without waiting for them to occur spontaneously.

Stage 2: FEM numerical simulation using COMSOL Multiphysics
The core of the analysis was a Finite Element Method (FEM) model developed in COMSOL Multiphysics, which faithfully reproduced the actual geometry of the system based on the technical documentation provided by the client. The simulations calculated the spatial distribution of current density and electrical power density within the fluid and at the material interfaces.
The results clearly highlighted two critical zones:
A transition zone where the geometry creates conditions for electric field concentration.
A thermally critical zone where the plastic material used—which acts as an excellent thermal insulator—prevents the dissipation of localized heat, contributing to a temperature increase.
In this second zone, the simulation also revealed that the system’s geometric configuration encourages the buildup of static product residues: material that is no longer in a liquid state but partially solidified. This material is subject to a dual effect of electric field concentration and localized overheating, which leads to the formation of bubbles. The combination of these factors creates the perfect conditions for the triggering of an electrical discharge.

Stage 3: Controlled experimental reproduction
The simulation formulated a clear and physically motivated hypothesis. The next step was to verify it experimentally in the laboratory by building a scaled-down mock-up specifically designed to replicate the critical conditions in a controlled and safe manner.
The mock-up made it possible to simulate limit operating conditions: high fluid temperature, reduced flow rate, and the presence of residues on the internal surfaces. Under these recreated conditions, the phenomenon manifested itself, validating the hypothesis formulated by the simulation and providing a solid foundation for the design recommendations.
The results: from understanding to solution

The combined analysis of field measurements, FEM simulation, and experimental replication produced a comprehensive and quantitatively sound description of the discharge triggering mechanism.
The cause of the destructive phenomena was found to be the combination of three concurrent factors:
Electric field concentration in geometrically critical zones of the system;
Accumulation of static product residues in those same areas;
Localized overheating amplified by the thermal insulation properties of the plastic material used.
The simultaneous presence of these three factors—each of which would be insufficient on its own—triggers a divergent thermal sequence that can lead to the localized melting of components.
This study provided the client with:
A clear understanding of the root cause, which was non-intuitive and impossible to identify using empirical tools alone.
A map of the system’s critical zones, indicating priority areas for intervention.
A validation methodology for testing corrective solutions.
Specific design guidelines to modify the geometry of the electrodes and fittings, reducing field concentration and limiting product stagnation.
A quantitative baseline for dimensioning and verifying modifications.
Ultimately, the client was able to launch a comprehensive revision of their technology armed with precise data and insights, completely eliminating the need for costly and risky trial-and-error experimentation.
Conclusions and cross-applications
The expertise applied in this project is relevant in all contexts where high-power electrical systems interact with materials or fluids under critical operating conditions.
Ohmic heating is a powerful technology, but it presents engineering challenges that require advanced analytical tools and a multidisciplinary approach. When a phenomenon occurs intermittently and is not reproducible, multiphysics simulation becomes a crucial tool for reducing diagnosis times and increasing confidence in the solutions adopted.
Food Pasteurisation
Chemical and pharmaceutical treatments
Electrolysis
Do you have a recurring technical issue that you can’t explain using the tools at your disposal? Let’s talk about it.
At InovaLab, we support companies developing innovative technologies throughout all the critical stages of the innovation process: from analysing and understanding the problem to formulating and implementing technically sound and verifiable solutions.

Talk to the engineers at inovaLab
We support companies developing innovative technologies throughout all the critical stages of the innovation process: from analysing and understanding the problem to formulating and implementing technically sound and verifiable solutions.
Get the latest news
Subscribe to our newsletter and receive all the latest updates on innovations, stories and events.
Do you require any information?
We are at your disposal! Contact us and we will respond to your request as soon as possible.